`timescale 1ns/1ps module tb; logic clk=0,rst=0,en=0,se=0,si=0; logic [3:0] d=0,q,sq; integer checks=0,expected; enabled_counter a(clk,rst,en,q); scan4 b(clk,rst,se,si,d,sq); task tick; begin #5;clk=1;#1;clk=0;#4;end endtask initial begin for(integer state=0;state<16;state++) for(integer r=0;r<2;r++) for(integer e=0;e<2;e++) begin rst=1;tick();rst=0;en=1;repeat(state) tick(); rst=r;en=e;tick();expected=r?0:(state+e)%16; if(q!==expected[3:0])$fatal(1,"counter state=%0d reset=%0d enable=%0d",state,r,e); checks++; end rst=0;en=0; for(integer state=0;state<16;state++) for(integer bitin=0;bitin<2;bitin++) begin se=0;d=state;tick();if(sq!==d)$fatal(1,"parallel load"); se=1;si=bitin;tick();expected=(state*2+bitin)%16; if(sq!==expected[3:0])$fatal(1,"scan shift");checks++; end // Synchronous reset must not change either state before an active edge. se=0;d=4'hf;tick();rst=1;#2;if(sq!==4'hf)$fatal(1,"reset changed without edge");tick(); if(sq!==0||q!==0)$fatal(1,"reset priority"); $display("PASS: %0d counter/scan cases plus reset-edge checks; RTL simulation only",checks);$finish; end endmodule